measurement of welding edge misalignment
Welding edge misalignment - misalignment in the location levels of welded parts in butt welded joints
![](https://cdn-ru.bitrix24.ru/b7836503/landing/209/209d9838e156a3707ef683b5d5187e2b/ustanova_T_2x.png 2x)
positioning the welding gauge
- Position the welding gauge below the weld.
- For greater stability of tge welding gauge when taking measurements, use the pivots
- Position the welding gauge perpendicular to the axis of the weld, close to the fusion line (end face).
![](https://cdn-ru.bitrix24.ru/b7836503/landing/3e9/3e98de28eeabd3f28c689a0b2675a55a/19_2x.png 2x)
˟the parameter measured during monitoring process is highlighted in red
measurement taking
- Pull the linear member 3 so that the taper gauge 5 is above the point corresponding to the fusion line (end) of the second part of the welded joint.
- Lower the top High-Lo arm 4 until the taper gauge 5 makes contact with the surface of the tested object at the point of measurement.
- Take the value of the desired parameter δ from the vertical scale H