measurement of welding edge misalignment

Welding edge misalignment  - misalignment in the location levels of welded parts in butt welded joints




  • Position the welding gauge below the weld.
  • For greater stability of tge welding gauge when taking measurements, use the pivots
  • Position the welding gauge perpendicular to the axis of the weld, close to the fusion line (end face).

˟the parameter measured during monitoring process is highlighted in red


  • Pull the linear member 3 so that the taper gauge 5 is above the point corresponding to the fusion line (end) of the second part of the welded joint. 
  • Lower the top High-Lo arm 4 until the taper gauge 5 makes contact with the surface of the tested object at the point of measurement. 
  • Take the value of the desired parameter δ from the vertical scale H